Manufacturer's name, model number (If any), 120V, 60Hz, Date of manufacture
UL split inspection recognition code "M", and hoover part no. 43576-175
Motor Test Requirements:
Motor supplier to run in the motor for a minimum of 8 minutes at 120V/60Hz High potential test Test potential is applied between current carrying elements And the armature core and stator core.
Test duration - 1 second
Test voltage - 1500VAC minimum
Reject limit = 0.75 mA
Insulation impedance - per UL 1017
Motor-Fan Performance at 120V, 60Hz (Reference Data)
Historical Hoover 1005 inspection limits -
Measured with fan eye wide open
Input watts - minimum 1060; maximum 1290
Motor speed - minimum 24500 RPM; maximum 29850 RPM
Motor-Fan Performance at 120V, 60Hz
Tested per ASTM 558 at 0.875" Orifice
Vacuum - 48" min
Input watts - 1400W Max
Current 10.0A Min; 12.0A Max
Sealed vacuum 80" min
Tap voltage between terminals - 12V ±IV
Measured at 0.875" Orifice
Reliability tests:
Life test - tested in Hoover Vacuum Cleaner
Moving on carpet
Test cycle - 8 min on; 2 min off
210 hours minimum on time using a weibull analysis (B-1)